How do I blow out my sprinkler system for the winter?
Shut off the irrigation water, connect a large enough air compressor — after the backflow preventer, never through it — and blow each zone in short cycles until only a fine mist remains. Wear ANSI-approved eye protection, do not stand over components, and keep air pressure within the limits for your pipe: Hunter Industries and Colorado State University Extension cap polyethylene pipe at 50 psi and PVC at 80 psi. Rain Bird’s written procedure has you set the regulator at 50 psi. If you do not have the right compressor or are unsure, hire a licensed irrigation contractor.
What you’ll need
- ANSI-approved safety glasses (and keep bystanders and pets away; CSU notes the noise can startle animals)
- An air compressor with a working pressure regulator, sized for the CFM your largest zone needs
- A blowout adapter or fitting on the downstream (house-to-heads) side of the backflow preventer — not upstream of it
- Access to the controller so you can run one zone at a time
- A helper is useful so one person watches heads and pressure while the other works the controller
Pressure and compressor size (read this first)
Pressure and air volume are not the same job. Too much pressure can blow nozzles off or break components; too little volume can leave water in low spots because the air skims over it (Colorado State University Extension).
- Pipe limits from Hunter and CSU Extension: do not exceed 50 psi for polyethylene (flexible black) pipe or 80 psi for PVC (rigid white) pipe. Stay below the maximum operating pressure of the lowest-rated part on that zone, including the sprinkler nozzles.
- Rain Bird’s step-by-step procedure says to set the compressor’s regulating valve to 50 psi, and earlier in the same article states that air pressure should not exceed 50 psi. The same Rain Bird article also mentions regulating a large compressor to 75–85 psi in a general equipment paragraph. Because that conflicts with Rain Bird’s own 50 psi procedure — and with Hunter and CSU’s 50 psi polyethylene cap — do not use 75–85 psi unless your manufacturer documentation for that exact system clearly allows it. When sources disagree, use the lower limit.
- CFM sizing: Hunter and CSU both use this rule of thumb: take the gallons-per-minute of the largest zone and divide by 7.5 to estimate the cubic feet per minute needed at the connection. Example from CSU: a 20 gpm zone would need about 2.66 CFM at 30 psi. Undersized compressors take longer and may not clear the lines.
- Do not fully charge a small tank and then dump that high-pressure burst into the mainline to compensate for low CFM (Hunter).
Steps
- Turn off the irrigation water supply at the isolation or stop-and-waste valve. Do not force a buried valve (CSU).
- Relieve pressure and attach the hose correctly. Close the backflow isolation valves so you are not sending air through the device. Connect the compressor hose to a fitting after the backflow preventer, with the compressor valve still closed (Hunter). If there is no downstream blowout fitting, CSU says one must be added before you can blow out the system.
- Open one zone before you introduce air. Hunter tells you to activate the station that is highest in elevation and farthest from the compressor. Rain Bird likewise says to activate a circuit — preferably the one farthest from the air connection — before starting the compressor, so pressure is not trapped against closed heads.
- Set the regulator and open the air slowly. Set the regulator to a safe limit (Rain Bird’s procedure: 50 psi; never above the pipe and component limits above). Slowly open the compressor valve so air enters gradually (Hunter). Increase airflow until the sprinkler heads pop up (Rain Bird).
- Run short cycles, one zone at a time. Work from the farthest/highest zone toward the closest (Hunter). Rain Bird says not to blow any circuit for more than two minutes at a time. Hunter and CSU prefer two or three short cycles per zone over one long cycle. Continue until no water is visible and only a fine mist comes from the heads, then stop. Do not keep blowing a dry zone; compressed air in dry pipe creates friction heat that can damage pipe, fittings, and gear-drive rotor seals (Hunter, Rain Bird, CSU).
- Change zones without trapping air. Rain Bird’s controller method: advance the timer to the next circuit and do not turn the controller off until the compressor is shut off. If you are opening valves by hand, Rain Bird says to turn the compressor off and let air purge before you switch valves, then open the next valve before you close the last one in a way that would leave the compressor pumping into a closed system. Never operate the compressor with all control valves closed.
- Shut down safely. After the last zone, Rain Bird says to leave one zone on while you shut off the compressor, then disconnect the hose after remaining air has dispersed. Release any leftover air pressure (Hunter).
- Winterize the backflow preventer after the blowout, not with it. Exercise isolation ball valves and test cocks several times, then leave the isolation valves about half open (45 degrees) and open the test cocks for winter (Hunter, CSU). Close test cocks before you turn water on in the spring, and open ball valves slowly to avoid water hammer.
- If manual drain valves are installed, close them after the blowout (Hunter). Remove flow sensors before blowing out a system that has them, and seal the pipe; reinstall later (Hunter).
- Set the controller to Off and leave it powered unless your own manual says otherwise (Hunter). Insulate or cap any remaining exposed components as needed.
Common mistakes and variations
Household garage compressors
A small portable electric compressor may reach 100 psi and still lack the air volume to push water out of a residential system. Older Michigan State University turf guidance (written for professionals) notes that a 185 CFM portable compressor is a common rental-yard machine for this work, and that volume matters more than high pressure, with a preferred operating range in that article of 40–50 psi. Renting a properly regulated machine is often more effective than over-pressurizing a shop compressor.
Pumps and wells
If the system has a pump, Colorado State University Extension says to drain it, remove it if you can, and store it inside; if it must stay in place, drain it and insulate it. Do not use the pump as the blowout path.
When you should not DIY
Oklahoma State University Extension tells homeowners that a professional blowout “isn’t something a homeowner should do on their own” because improper pressure can damage the system. Hunter similarly says it is best to call a professional. If you cannot measure or regulate pressure, do not have a downstream connection, or have a reduced-pressure backflow device you do not know how to drain, hire an irrigation contractor.
FAQ
What pressure should I use?
Hunter Industries and Colorado State University Extension say not to exceed 50 psi for polyethylene (flexible black) pipe or 80 psi for PVC (rigid white) pipe, and to stay below the maximum operating pressure of the lowest-rated component in that zone. Rain Bird’s step-by-step blowout procedure tells you to set the compressor’s regulator to 50 psi and also states that air pressure should not exceed 50 psi. Use the lowest applicable limit for your pipe and heads.
Will a pancake or small shop compressor work?
Volume matters as much as pressure. Colorado State University Extension and Hunter warn that if the compressor cannot supply enough cubic feet per minute, air can ride over the top of the water and leave water in low spots. Hunter says not to fill the tank and then dump a blast of high-pressure air into the mainline to make up for low CFM. A common sizing formula in both Hunter and CSU materials is the largest zone’s gallons per minute divided by 7.5, which gives the CFM needed at the connection.
Can I blow air through the backflow preventer?
No. Hunter says compressed air should not be blown through any backflow device or pump: blow out the irrigation system first, then drain the backflow or pump. Colorado State University Extension says pressure vacuum breaker and reduced-pressure backflow devices must never be blown out with compressed air because the rubber seals can melt from the heat of the air.
How long should I run each zone?
Hunter says each station should run until no water can be seen exiting the heads, about two minutes or more, and that two or three short cycles are better than one long cycle. Rain Bird says not to blow any circuit for more than two minutes at a time because heat from compressed air can damage pipes and other components, and to repeat the cycle two or more times until only a fine mist appears. Stop once a zone is dry; blowing air through dry pipe can create damaging heat.
Sources
We checked these pages and documents while writing this guide. Follow your own manual if it differs.
- Winterizing Your Irrigation System — Hunter IndustriesOfficial warning language, 50 psi polyethylene / 80 psi PVC limits, CFM formula, attach-after-backflow rule, zone order, and short-cycle guidance.
- Valves – Winterization Procedures — Hunter IndustriesAdditional Hunter support page repeating the 50/80 psi caps and the warning never to exceed 80 psi.
- Fall is Blow-Out Season — Rain BirdOctober 20, 2025 Rain Bird article: 50 psi regulator setting, two-minute cycle limit, open-a-valve-first rule, and rotor overheating warning.
- Home Sprinkler Systems: Preparing Your Sprinkler System for Winter — Colorado State University ExtensionReviewed August 2025. CFM formula, 40–80 psi discussion with 50/80 pipe caps, do not blow through PVB/RP devices, and backflow winter positions.
- Winterizing your irrigation system — Michigan State University turf archive (2011)Professional-oriented article on compressor volume (including 185 CFM rentals), preferred 40–50 psi, and heat buildup. Cited for context, not as a substitute for your manufacturer’s limits.
- Tips for Winterizing a Home Landscape Irrigation System — Oklahoma State University ExtensionRecommends hiring a professional for compressed-air winterization.